60 Minute FE/BR Louvers
The FDI-L60 Forced Entry Resisting Louver System is capable of resisting 60 minutes of forced entry assault and defeating multiple
impacts of 7.62mm NATO and 5.56mm projectiles as defined by applicable U.S. Government Standards.
Features
DOS Codes and Model Numbers
Basic Use
This louver system is used to provide protection in those areas susceptible to mob or terrorist attacks. Applications are likely to be at safe haven rooms where prolonged protection is required. The primary application of louvers is areas where ventilation is required, such as generator room walls.
Limitations
This louver has been designed to meet the rigid specifications developed by the U.S. Government for 60-minute forced entry and high power rifle impact. It is recommended that each end user determine the ballistic and forced entry threat and choose the appropriate product to meet and resist that threat.
Applicable Standard
Specifications/Construction
Louver construction: Louvers are constructed of ballistic steel plates and ¼” angles.
Louver Frame Construction: Louver frame assembly is constructed of steel tubes and plates. Framing dimensions are 2 ¼” wide x 10” deep. Louver frames are completely fabricated at factory and shipped with louvers. All louvers are pre-tested for fit to ease field installation. All joint connections are welded to provide a rigid assembly when installed. Frames are predrilled to accept ½” anchors 8” on center. Shims are provided to take up a space at each anchor.
Sub-frames: To meet forced entry requirements of DOS SD.STD-01.01 (Rev. G amended), steel tube subframes ¼” wall thickness minimum, must be attached to concrete or masonry with Hilti® Epoxy Anchoring System. An acceptable alternative is the use of steel embeds, ½” thick minimum. These systems are included as options in our product line.
Finish: All Louvers and frames are furnished prime painted, ready for final finish in field. Options: Factory can apply polyurethane enamel; color chart is available upon request.
Weights and Measurements
Standard Louver:
Louver Thickness: 7”
Frame Depth: 10”
Louver Size: 96” x 96” Tested
Shipping Weight: 100 lbs / sq. ft.
The FDI-L60 Forced Entry Resisting Louver System is capable of resisting 60 minutes of forced entry assault and defeating multiple
impacts of 7.62mm NATO and 5.56mm projectiles as defined by applicable U.S. Government Standards.
Features
- Designed to meet 60 Minute forced entry protection
- Multi-impact high power rifle resistant
- Heavy duty steel construction
- Louver and frame shipped loose for ease of handling
- opaque only
DOS Codes and Model Numbers
- DOS 2133 GPL-60R-FDI-01
Basic Use
This louver system is used to provide protection in those areas susceptible to mob or terrorist attacks. Applications are likely to be at safe haven rooms where prolonged protection is required. The primary application of louvers is areas where ventilation is required, such as generator room walls.
Limitations
This louver has been designed to meet the rigid specifications developed by the U.S. Government for 60-minute forced entry and high power rifle impact. It is recommended that each end user determine the ballistic and forced entry threat and choose the appropriate product to meet and resist that threat.
Applicable Standard
- DOS SD.STD-01.01 (Rev. G amended)
Specifications/Construction
Louver construction: Louvers are constructed of ballistic steel plates and ¼” angles.
Louver Frame Construction: Louver frame assembly is constructed of steel tubes and plates. Framing dimensions are 2 ¼” wide x 10” deep. Louver frames are completely fabricated at factory and shipped with louvers. All louvers are pre-tested for fit to ease field installation. All joint connections are welded to provide a rigid assembly when installed. Frames are predrilled to accept ½” anchors 8” on center. Shims are provided to take up a space at each anchor.
Sub-frames: To meet forced entry requirements of DOS SD.STD-01.01 (Rev. G amended), steel tube subframes ¼” wall thickness minimum, must be attached to concrete or masonry with Hilti® Epoxy Anchoring System. An acceptable alternative is the use of steel embeds, ½” thick minimum. These systems are included as options in our product line.
Finish: All Louvers and frames are furnished prime painted, ready for final finish in field. Options: Factory can apply polyurethane enamel; color chart is available upon request.
Weights and Measurements
Standard Louver:
Louver Thickness: 7”
Frame Depth: 10”
Louver Size: 96” x 96” Tested
Shipping Weight: 100 lbs / sq. ft.