FDI
  • Home
  • Security Products
  • Doors
    • Door Styles
    • 5 Minute FE Door
    • 15 Minute Door
    • 60 Minute FE/BR Door
    • SHW Groups
  • Windows
    • Window Styles
    • 5 Minute Window
    • 15 Minute FE/BR Window
    • 5&15 Minute FE/BR Teller Window
  • Louvers
  • Contact
  • EZ Booth
  • Our Founders
  • Photo Gallery


FDI-15M / FDI-NGC15M Bullet & Forced Entry Resistant Door System
Features

·        Designed to Meet 15-Minute Forced Entry Protection
·        High Power Rifle Resistant, 7.62mm & 5.56mm                             
·        Glazing Components Easily Replaced                                              
·        Single Vision, Double Vision, Opaque
·        Fire Rating to meet UL / WH 90minute     (FDI15M Opaque Only)

DOS Codes & Model Numbers:

FDI-15M                                                                                                                             
w/Vision          ·        DOS 1123 GDT-15R-FDI-02  
Opaque            ·        DOS 2123 GDO-15R -FDI-01                              Available Styles:                 ​

FDI-NGC15M                                                                                                
w/Vision          ·        DOS 1123 GDT-15R -FDI-02B
Opaque            ·        DOS 2123 GDO-15R -FDI-01B

Product Description  
          The FDI15M and FDI-NGC15M Forced Entry Resisting Door Systems are capable of resisting 15 minutes of forced entry assault and defeating multiple impacts of 7.62mm NATO and 5.56mm projectiles as defined by applicable U.S. Government Standards.

Basic Use
            This door system is used to provide protection in those areas susceptible to mob or terrorist attacks.  Applications are likely to be at main security access control points and at other designated egress points.

Limitations    
        This door has been designed to meet the high power rifle and 15-minute forced entry requirements as set forth in DOS SD-STD-01.01, Rev.G (amended).  It is recommended that each end user determine the forced entry threat and choose the correct product to meet and resist that threat.

Specifications/Construction 
Door construction:  Doors and frames are full flush construction of ballistic steel plates and 1 ½” steel tube.  Vertical jambs and header contain bullet-resisting material equal to protection level of the door. 

Door Frame Construction:  Door frame assembly is constructed of steel tubes.  Framing dimensions are 1 ¾” wide x 5” deep.  Door frames are completely fabricated at factory and shipped with doors attached.  All doors are pre-tested for all locking functions, clearances, and ease of operation, to ease field installation.  All joint connections are welded to provide a rigid assembly when installed.  The doorstop is built into the frame.  Frames are predrilled to accept ½” anchors 12” on center.  Shims are provided to take up a space at each anchor.  Wiring diagrams are shipped enclosed in the hardware packages.

Hardware Assembly:  Each door is equipped as follows:

               a.       Door Closer (LCN 4041 CUSH)
               b.      (2) Forced Entry Locks (Adams Rite 1850S w/ 15tt Thumbturns)
               c.       2 ea Brookfield i8513 5” x 5 ½” needle bearing hinges
               d.      Aluminum Threshold (Pemko 177AV36)
               e.      Weather Stripping (Pemko SS88D17)

Optional Hardware:  Refer to the hardware section of this catalog for additional hardware information.  You must select a lockset, pull handle, or panic device that suits your application.  Most hardware is shipped pre-assembled with the door unit.

Subframes:  To meet forced entry requirements of DOS SD.STD-01.01 (Rev. G amended), steel tube subframes  ¼” wall thickness minimum, must be attached to concrete or masonry with Hilti® Epoxy Anchoring System.  An acceptable alternative is the use of steel embeds, ½” thick minimum.  These systems are included as options in our product line.
   
Finish:  All doors and frames are furnished prime painted, ready for final finish in field.  Options: Factory can apply polyurethane enamel; color chart is available upon request. Doors can also be fitted with various types of architectural metals.

Glazing:  Glazing materials shall be of a type approved by H.P. White Laboratory, Inc. for forced-entry resistance.  Size to be limited to 20” x 30” vision area.  Glazing is replaceable without removing the door from the frame.

Applicable Standard  ·       
                  DOS SD.STD-01.01 (Rev. G amended)

Weights and Measurements
Standard Door:
Door Thickness:                      2”
Frame Depth:                          5 ½” (FDI-15M); 5” (FDI-NGC15M)
Door Size:                               36” x 84”
Frame Size:                             40” x 86” (FDI-15M); 39 ½” x 86” (FDI-NGC15M)
Rough Opening:                      41 ½” x 86 ¾” (FDI-15M); 40” x 86 ¼” (FDI-NGC15M)
Gap Cover Dimension             41” x 86 ½” (FDI-15M only)
Shipping Weight:                    1500 lbs

​
​

Security Products

Doors

Windows

Louvers

Contact

Fabrication Designs, Inc   7463 New Ridge Rd   Hanover, Maryland  21076   (410)-850-0042    [email protected]       Copyright © Fabrication Designs, Inc. 2017
  • Home
  • Security Products
  • Doors
    • Door Styles
    • 5 Minute FE Door
    • 15 Minute Door
    • 60 Minute FE/BR Door
    • SHW Groups
  • Windows
    • Window Styles
    • 5 Minute Window
    • 15 Minute FE/BR Window
    • 5&15 Minute FE/BR Teller Window
  • Louvers
  • Contact
  • EZ Booth
  • Our Founders
  • Photo Gallery